기관회원 [로그인]
소속기관에서 받은 아이디, 비밀번호를 입력해 주세요.
개인회원 [로그인]

비회원 구매시 입력하신 핸드폰번호를 입력해 주세요.
본인 인증 후 구매내역을 확인하실 수 있습니다.

회원가입
서지반출
감각신경성난청인의 비선형 주파수압축보청기 착용효과: 사례보고
[STEP1]서지반출 형식 선택
파일형식
@
서지도구
SNS
기타
[STEP2]서지반출 정보 선택
  • 제목
  • URL
돌아가기
확인
취소
  • 감각신경성난청인의 비선형 주파수압축보청기 착용효과: 사례보고
  • Effects of Non-linear Frequency Compression Hearing Aids for Subjects with Sensorineural Hearing Loss: Case Report
저자명
주연미,이경원
간행물명
Audiology and Speech ResearchKCI,SCOPUS
권/호정보
2015년|11권 1호(통권20호)|pp.63-69 (7 pages)
발행정보
한국청각언어재활학회|한국
파일정보
정기간행물|KOR|
PDF텍스트(0.39MB)
주제분야
특수교육학
서지반출

국문초록

영문초록

The purpose of this study was to report three cases about how aided hearing threshold levels, word recognition score (WRS) and subjective responses changed when the frequency compression (FC) function was deactivated or activated in non-linear frequency compression hearing aid. Three subjects (6 ears) with sensorineural hearing loss bilaterally and with no history of wearing hearing aids before participated in this study. All the participants wore receiver-in-the canal type digital hearing aids with 20 channels. After the FC function was activated, the results showed better aided hearing threshold levels by 5 ~ 20 dB and improved WRS by 6 ~ 14% mostly in high frequency range compared to those of non-frequency compression (NFC). Their subjective responses of sound qualities showed positively better compared to those of the NFC. This study strongly suggests that in case of people whose hearing loss is severe in the high frequency range, FC hearing aids can help to result in better WRS. However, the future study to accurately evaluate an effect of FC hearing aid used for subjects with sensorineural hearing loss will need more elaborate design and to evaluate the changes of gain in both psychosocial and listening-environmental aspects by using other questionnaires.

목차

INTRODUCTION
MATERIALS & METHODS
RESULTS
DISCUSSIONS & CONCLUSIONS
REFERENCES

참고문헌 (16건)

  • 김진숙, 임덕환, 홍하나, 신현욱, 이기도, 홍빛나 외. (2008). 한국표준 일반용 단음절어표 개발. 청능재 활, 4(2), 126-140.
  • 이경원. (2014). 비선형 보청기의 전기음향적 조절에 따른 역동범위, 신호대잡음비 및 자모음비의 변화 와 적합. 청능재활, 10(3), 190-197.
  • 이경원, 이재희, & 이정학. (2008). 한국어음을 이용한 다화자잡음의 개발 시안. 청능재활, 4(1), 24-27.
  • 주현민, 김형재, & 임덕환. (2012). 주파수이동기능 보 청기 적합이 고주파수 영역 청력손실자의 한국어 단어인지도에 미치는영향에 대한 사례. 청능재활, 8(2), 249-251.
  • 한국산업표준. (2009). KS I ISO 8253-3. 음향학-청력 검사방법-제3부 : 어음청각검사. 지식경제부 기술 표준원.
  • Barker, C., Dillon, H., & Newall, P. (2001). Fitting low ratio compression to people with severe and profound hearing losses. Ear and Hearing, 22, 130-141.
  • Boike, K. T. & Souza, P. E. (2001). Effect of compression ratio on speech recognition and speech-quality ratings with wide dynamic range compression amplification. Journal of Speech, Language, and Hearing Research, 43, 456-468.
  • Friesen, L. M., Shannon, R. V., Baskent, D., & Wang, X. (2003). Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants. Journal of the Acoustical Society of America, 110, 1150-1163.
  • Galster, J. A., Valentine, S., Dundas, J. A., & Fitz, K. (2011). Spectral iQ: Audibly improving access to high-frequency sounds. Starkey Laboratories.
  • Glista, D., Scollie, S., Bagatto M., Seewald, R., Parsa, V., & Johnson, A. (2009). Evaluation of non-linear frequency compression: Clinical outcomes. International Journal of Audiology, 48, 632-644.
  • Keidser, G. & Grant, F. (2001). The preferred number of channels (one, two, or four) in NAL-NL1 prescribed wide dynamic range compression (WDRC) devices. Ear and Hearing, 22, 516-527.
  • Kuk, F. (2007). Critical factors in ensuring efficacy of frequency transposition. Part 1: Individualizing the start frequency. Hearing Review, 14, 60-67.
  • Reed, C. M., Schultz, K. I., Braida, L. D., & Durlach, N. I. (1985). Discrimination and identification of frequency lowered speech in listeners with highfrequency hearing impairment. Journal of the Acoustical Society of America, 78, 2139-2141.
  • Robinson, J. D., Baer, T., & Moore, B. C. (2007). Using transposition to improve consonant discrimination and detection for listeners with severe high-frequency hearing loss. International Journal of Audiology, 46, 293-308.
  • Simpson, A., Hersbach, A. A., & McDermott, H. J. (2005). Improvements in speech perception with an experimental nonlinear frequency-compression hearing device. International Journal of Audiology, 44, 281- 292.
  • Von Hapsburg, D. & Bahng, J. (2006). Acceptance of background noise levels in bilingual (Korean- English) listeners. Journal of the American Academy of Audiology, 17, 649-658.
구매하기 (3,000)
추천 연관논문